NOKOV
Website
XingYing3.4-EN
XingYing3.4-EN
  • XINGYING3.4
    • Beginner's Guide
      • Hardware Setup
      • Software Quick Start
    • Ⅰ. System Overview
      • 1. NOKOV Motion Capture System
      • 2. Hardware Components
    • Ⅱ. System and Camera Setup
      • 1. Camera Models
      • 2. Hardware Assembly
      • 3. Camera Connection
      • 4. Focusing and Aperture
    • Ⅲ. Software Installation and Launch
      • 1. Network Settings
      • 2. Firewall Settings
      • 3. Software Installation
      • 4. Software Launch
    • Ⅳ. Getting Started with XINGYING 3.0
      • 1. Menu Bar
      • 2. Toolbar
    • Ⅴ. Calibration
      • 1. Calibration Settings
      • 2. Calibration Preparation
    • Ⅵ. Views
      • 1. Device Properties
      • 2. Assets Properties
      • 3. Data Casting
    • Ⅶ. Software Settings
      • 1. Recording Settings
      • 2. View Settingss
      • 3. AI Settings
      • 4. Preferences
      • 5. Other Settings
    • Ⅷ. Calibration Categories
      • 1. Preparing for Calibration
      • 2. Basic Calibration
      • 3. Updating Calibration
      • 4. Origin Point Calibration
      • 5. Partial Calibration
      • 6.Ground Calibration
      • 7. Calibration-free (Anchor Calibration)
    • Ⅸ. Markerset Creation
      • 1. Rigid
      • 2. Body
      • 3. Custom template
      • 4. Agent
      • 5. Asset Library
      • 6.Probe
      • 7.Scene library
    • Ⅹ. Data Collection and Fast Playback
      • 1. Data Collection
      • 2. Fast Playback
    • Ⅺ. Data Analysis
      • 1. Analyze Graphs
      • 2. Skeleton Graphs
      • 3. Analog Graphs
      • 4. Force Plate Data
      • 5. Health Graphs
      • 6. VMarker Graphs
    • Ⅻ. Data Processing
      • 1. Importing Data
      • 2. Create MarkerSet (Rigid)
      • 3. Use Existing MarkerSet
      • 4. Data Restoration
      • 5. Template Creation
      • 6. Template Identification and Tracking
      • 7. Data Rectification
      • 8. Use MarkerSet in Real-Time
      • 9. Marker Editing
      • 10.Marker switching
      • 11.Multi-frame recognition
    • XIII. Data Export
      • 1. Ly Files
      • 2. XRS Files
      • 3. TRC Files
      • 4. BVH Files
      • 5. HTR Files
      • 6. FBX Files
      • 7. Dynamics Files
      • 8. C3D Files
      • 9. ANC Files
      • 10. Exporting Forces Files
      • 11. Packing motion capture data
    • XIV. Human Body Template
      • 1. 53 Markers and Skeleton Definitions
      • 2. Helen Hayes Model
      • 3. Gloved Setup for 53-Marker Template
      • 4.CGM2 Body Model
      • 5.Finger Marker Point Instructions
    • XV. Data Retargeting
      • 1. Importing Model Assets
    • XVI. Third-Party Integrations
      • Force Plates
        • Bertec
        • KUNWEI
        • AMTI
        • Kistler
        • Aili Intelligent
        • General configuration
          • Import/Export Force Plate Config Files
          • Force and Torque
          • Other Configurations
      • EMG
        • ZHIYUNWEI
        • Distributed Wireless Electromyography
        • Delsys
        • Cometa
        • Noraxon
      • High-Speed Industrial Cameras
        • Standard industrial camera
        • Alkeria
        • HUIDIAN
        • DAHENG
        • DITECT
        • Network camera
        • Instructions for Hikvision Cameras
      • Inertial Gloves
        • Glove management
        • Manus
        • VRTRIX
    • XVII. Plugins & SDKs
      • 1. Unreal Engine (UE) Plugin
      • 2. Guide to Connecting Devices and Integrating VRPN Data with UE
      • 3. Use VRPN Data to Drive Rigid Body in UE
      • 4. MotionBuilder Plugin
      • 5. Maya Plugin
      • 6. Unity Plugin
      • 7. IClone Plugin
      • 8. Application of TimeCode in UE
      • 9.C4D Plugin
      • 10.Blender plugin
    • XVIII. UDP Capture Broadcast/Triggering
      • 1. Remote Control
      • 2. Remote Trigger
    • XVIIII.Log
      • 1.DisplayLog
Powered by GitBook
On this page
  1. XINGYING3.4
  2. XIII. Data Export

3. TRC Files

Previous2. XRS FilesNext4. BVH Files
  1. The TRC file is a coordinate data file for points, exporting the data coordinates of both named and unnamed points contained in the cap file into a single file.

  2. In Edit Mode, after loading the capture data, click "File" and select "Export TRC File". The system will prompt that the export of the TRC file was successful; then click "Confirm" (13.3.1). The system saves the TRC file to the working path by default. The naming convention is cap file name + '-' + MarkerSet name + '.xrs'. The coordinate data of unnamed points is also exported by default, using the naming convention: cap file name + '-' + 'unnamed' + '.xrs'.

  3. TRC files can be opened in Excel format, with data formats including "frame, time, timestamp, xyz coordinates" (13.3.2).


Saving of R-Calculated Markers

  • In post-processing mode, enable "Show Inverse Kinematic Markers", then click the solve button on the top toolbar. After the inverse kinematic markers are displayed in the 3D view, go to File -- Export TRC File. Open the TRC file using Excel, and it will show the XYZ data for each frame of the calculated markers for each named point. In the TRC file, the name of the inverse kinematic markers is "RCalc_marker name" (13.3.3).

13.3.1
13.3.2