NOKOV
Website
XingYing3.4-EN
XingYing3.4-EN
  • XINGYING3.4
    • Beginner's Guide
      • Hardware Setup
      • Software Quick Start
    • Ⅰ. System Overview
      • 1. NOKOV Motion Capture System
      • 2. Hardware Components
    • Ⅱ. System and Camera Setup
      • 1. Camera Models
      • 2. Hardware Assembly
      • 3. Camera Connection
      • 4. Focusing and Aperture
    • Ⅲ. Software Installation and Launch
      • 1. Network Settings
      • 2. Firewall Settings
      • 3. Software Installation
      • 4. Software Launch
    • Ⅳ. Getting Started with XINGYING 3.0
      • 1. Menu Bar
      • 2. Toolbar
    • Ⅴ. Calibration
      • 1. Calibration Settings
      • 2. Calibration Preparation
    • Ⅵ. Views
      • 1. Device Properties
      • 2. Assets Properties
      • 3. Data Casting
    • Ⅶ. Software Settings
      • 1. Recording Settings
      • 2. View Settingss
      • 3. AI Settings
      • 4. Preferences
      • 5. Other Settings
    • Ⅷ. Calibration Categories
      • 1. Preparing for Calibration
      • 2. Basic Calibration
      • 3. Updating Calibration
      • 4. Origin Point Calibration
      • 5. Partial Calibration
      • 6.Ground Calibration
      • 7. Calibration-free (Anchor Calibration)
    • Ⅸ. Markerset Creation
      • 1. Rigid
      • 2. Body
      • 3. Custom template
      • 4. Agent
      • 5. Asset Library
      • 6.Probe
      • 7.Scene library
    • Ⅹ. Data Collection and Fast Playback
      • 1. Data Collection
      • 2. Fast Playback
    • Ⅺ. Data Analysis
      • 1. Analyze Graphs
      • 2. Skeleton Graphs
      • 3. Analog Graphs
      • 4. Force Plate Data
      • 5. Health Graphs
      • 6. VMarker Graphs
    • Ⅻ. Data Processing
      • 1. Importing Data
      • 2. Create MarkerSet (Rigid)
      • 3. Use Existing MarkerSet
      • 4. Data Restoration
      • 5. Template Creation
      • 6. Template Identification and Tracking
      • 7. Data Rectification
      • 8. Use MarkerSet in Real-Time
      • 9. Marker Editing
      • 10.Marker switching
      • 11.Multi-frame recognition
    • XIII. Data Export
      • 1. Ly Files
      • 2. XRS Files
      • 3. TRC Files
      • 4. BVH Files
      • 5. HTR Files
      • 6. FBX Files
      • 7. Dynamics Files
      • 8. C3D Files
      • 9. ANC Files
      • 10. Exporting Forces Files
      • 11. Packing motion capture data
    • XIV. Human Body Template
      • 1. 53 Markers and Skeleton Definitions
      • 2. Helen Hayes Model
      • 3. Gloved Setup for 53-Marker Template
      • 4.CGM2 Body Model
      • 5.Finger Marker Point Instructions
    • XV. Data Retargeting
      • 1. Importing Model Assets
    • XVI. Third-Party Integrations
      • Force Plates
        • Bertec
        • KUNWEI
        • AMTI
        • Kistler
        • Aili Intelligent
        • General configuration
          • Import/Export Force Plate Config Files
          • Force and Torque
          • Other Configurations
      • EMG
        • ZHIYUNWEI
        • Distributed Wireless Electromyography
        • Delsys
        • Cometa
        • Noraxon
      • High-Speed Industrial Cameras
        • Standard industrial camera
        • Alkeria
        • HUIDIAN
        • DAHENG
        • DITECT
        • Network camera
        • Instructions for Hikvision Cameras
      • Inertial Gloves
        • Glove management
        • Manus
        • VRTRIX
    • XVII. Plugins & SDKs
      • 1. Unreal Engine (UE) Plugin
      • 2. Guide to Connecting Devices and Integrating VRPN Data with UE
      • 3. Use VRPN Data to Drive Rigid Body in UE
      • 4. MotionBuilder Plugin
      • 5. Maya Plugin
      • 6. Unity Plugin
      • 7. IClone Plugin
      • 8. Application of TimeCode in UE
      • 9.C4D Plugin
      • 10.Blender plugin
    • XVIII. UDP Capture Broadcast/Triggering
      • 1. Remote Control
      • 2. Remote Trigger
    • XVIIII.Log
      • 1.DisplayLog
Powered by GitBook
On this page
  1. XINGYING3.4
  2. Ⅷ. Calibration Categories

6.Ground Calibration

Previous5. Partial CalibrationNext7. Calibration-free (Anchor Calibration)

Last updated 9 months ago

  1. Before using this function, please calibrate the system first by Initial Calibration. After the calibration is completed, place the Marker surface calibration point on the site. It is necessary to place 3-5 Marker points in the capture scene, and ensure that the position of the placed Marker points is in the even part of the capture scene.

Ground Calibration:

Switch to 2D view, click on Calibration, select Ground Calibration, keep default parameters and name, double-check the number of marker points in the area, click on Calibration. After calibration, all midpoints in the 3D view should be on the ground. Click on Save, a file dialog will appear, click OK (8.6.1).

The number of marker points must be greater than 3, and there should be no other extraneous points in the area except for the placed points.

Height Offset:

When specifying the radius for the Marker, please reference a point. Ensure that after calibration, the Marker will be displayed completely on the ground.

The default is 0.

Note: The unit of measurement for the value is in millimeters.