NOKOV
Website
XingYing4.1-EN
XingYing4.1-EN
  • XINGYING4.0
    • Beginner's Guide
      • Hardware Setup
      • Software Quick Start
    • Ⅰ. System Overview
      • 1. NOKOV Motion Capture System
      • 2. Hardware Components
    • Ⅱ. System and Camera Setup
      • 1. Camera Models
      • 2. Hardware Assembly
      • 3. Camera Connection
      • 4. Focusing and Aperture
    • Ⅲ. Software Installation and Launch
      • 1. Network Settings
      • 2. Firewall Settings
      • 3. Software Installation
      • 4. Software Launch
      • 5. Software Activation
      • 6.Lens configuration
    • Ⅳ. Getting Started with XINGYING 4.0
      • 1. Menu Bar
      • 2. Toolbar
    • Ⅴ. Calibration
      • 1. Calibration Settings
      • 2. Calibration Preparation
      • 3. Zoning Calibration
      • 4. T Calibration Progress Prompt
      • 5. Reference Video Calibration
    • Ⅵ. Views
      • 1. Device Properties
      • 2. Assets Properties
      • 3. Data Casting
    • Ⅶ. Software Settings
      • 1. Recording Settings
      • 2. View Settingss
      • 3. AI Settings
      • 4. Preferences
      • 5. Other Settings
    • Ⅷ. Calibration Categories
      • 1. Preparing for Calibration
      • 2. Basic Calibration
      • 3. Updating Calibration
      • 4. Origin Point Calibration
      • 5. Partial Calibration
      • 6.Ground Calibration
      • 7. Calibration-free (Anchor Calibration)
      • 8. side-mounted Camera / inverted Camera
    • Ⅸ. Markerset Creation
      • 1. Rigid
      • 2. Body
      • 3. Custom template
      • 4. Agent
      • 5. Asset Library
      • 6.Probe
      • 7.Scene library
    • Ⅹ. Data Collection and Fast Playback
      • 1. Data Collection
      • 2. Fast Playback
    • Ⅺ. Data Analysis
      • 1. Analyze Graphs
      • 2. Skeleton Graphs
      • 3. Analog Graphs
      • 4. Force Plate Data
      • 5. Health Graphs
      • 6. VMarker Graphs
    • Ⅻ. Data Processing
      • 1. Importing Data
      • 2. Create MarkerSet (Rigid)
      • 3. Use Existing MarkerSet
      • 4. Data Restoration
      • 5. Template Creation
      • 6. Template Identification and Tracking
      • 7. Data Rectification
      • 8. Use MarkerSet in Real-Time
      • 9. Marker Editing
      • 10.Marker switching
      • 11.Multi-frame recognition
    • XIII. Data Export
      • 1. Ly Files
      • 2. XRS Files
      • 3. TRC Files
      • 4. BVH Files
      • 5. HTR Files
      • 6. FBX Files
      • 7. Dynamics Files
      • 8. C3D Files
      • 9. ANC Files
      • 10. Exporting Forces Files
      • 11. Packing motion capture data
    • XIV. Human Body Template
      • 1. 53 Markers and Skeleton Definitions
      • 2. Helen Hayes Model
      • 3. Gloved Setup for 53-Marker Template
      • 4.CGM2 Body Model
      • 5.Finger Marker Point Instructions
      • 6. Explanation of 59-Point Finger Attachment
      • 7. Explanation of 63-Point Finger Attachment
      • 8.PlugIn Gait Marker Placement Instructions
    • XV. Data Retargeting
      • 1. Importing Model Assets
    • XVI. Third-Party Integrations
      • Force Plates
        • Bertec
        • KUNWEI
        • AMTI
        • Kistler
        • Aili Intelligent
        • General configuration
          • Import/Export Force Plate Config Files
          • Force and Torque
          • Other Configurations
      • EMG
        • ZHIYUNWEI
        • Distributed Wireless Electromyography
        • Delsys
        • Cometa
        • Noraxon
      • High-Speed Industrial Cameras
        • Standard industrial camera
        • Alkeria
        • HUIDIAN
        • DAHENG
        • DITECT
        • Network camera
        • FLIR Industrial Camera
      • Inertial Gloves
        • Glove management
        • Manus
        • VRTRIX
        • Diver-X
          • Installation and Calibration Configuration
          • Creating a Human Body Model with Gloves
    • XVII. Plugins & SDKs
      • 1. Unreal Engine (UE) Plugin
      • 2. Guide to Connecting Devices and Integrating VRPN Data with UE
      • 3. Use VRPN Data to Drive Rigid Body in UE
      • 4. MotionBuilder Plugin
      • 5. Maya Plugin
      • 6. Unity Plugin
      • 7. IClone Plugin
      • 8. Application of TimeCode in UE
      • 9.C4D Plugin
      • 10.Blender plugin
      • 11.Open VR Plugin
      • 12. Communication between Ros2 and Nokov
    • XVIII. UDP Capture Broadcast/Triggering
      • 1. Remote Control
      • 2. Remote Trigger
    • XVIIII.Log
      • 1.DisplayLog
Powered by GitBook
On this page
  1. XINGYING4.0
  2. XVI. Third-Party Integrations
  3. Force Plates

KUNWEI

  1. Digital force plates support domestic Kunwei and Aili force plates. If you are using Aili force plates, please contact our engineering team for assistance. The following configuration instructions are only for Kunwei force plates.

  2. Connect the Kunwei force plate to power. Due to the default IP subnet of the Kunwei force plate being different from that of the motion capture system, you need to change the IP of the Kunwei force plate to the 10.1.1.X subnet.

  3. The method for setting the IP of the Kunwei force plate is to contact Kunwei manufacturer directly. If the user chooses not to use the 10.1.1.X IP address, then please use a dual-network card host and ensure that the IP of the Kunwei force plate is correctly configured.

  4. After configuring the force plate IP, you can open the command prompt and enter the configured IP address to see if it can be pinged. Once communication is successful, you can proceed to configure the force plate parameters in the motion capture software.

    To configure the force plate in XINGYING:

    1. Open XINGYING and click on the force plate menu.

    2. Select 'Force Plate Parameter Settings.'

    3. In the force plate parameter settings window, under 'Other Configurations,' check 'Digital Force Plate (Network).'

    4. Click the '+' button to add a Kunwei force plate.

    5. Select the added force plate and configure its parameters on the right side.

  5. In the 'IP Address' input box, enter the IP address you have set for your force plate. For example, if the IP address of your Kunwei force plate is 10.1.1.194, then enter 10.1.1.194 in the IP address field. In the 'Port' field, enter the corresponding port number. For example, if the IP address of your Kunwei force plate is 10.1.1.19X, then its port number is 888X.

  6. When you have multiple Kunwei force plates, please repeat steps 1-5 mentioned above for each force plate. Also, ensure that you correctly set the center of the force plate according to its actual placement.

  7. After completing all parameter configurations , please click the 'Apply' button to save your changes.

PreviousBertecNextAMTI