NOKOV
Website
XingYing4.1-EN
XingYing4.1-EN
  • XINGYING4.0
    • Beginner's Guide
      • Hardware Setup
      • Software Quick Start
    • Ⅰ. System Overview
      • 1. NOKOV Motion Capture System
      • 2. Hardware Components
    • Ⅱ. System and Camera Setup
      • 1. Camera Models
      • 2. Hardware Assembly
      • 3. Camera Connection
      • 4. Focusing and Aperture
    • Ⅲ. Software Installation and Launch
      • 1. Network Settings
      • 2. Firewall Settings
      • 3. Software Installation
      • 4. Software Launch
      • 5. Software Activation
      • 6.Lens configuration
    • Ⅳ. Getting Started with XINGYING 4.0
      • 1. Menu Bar
      • 2. Toolbar
    • Ⅴ. Calibration
      • 1. Calibration Settings
      • 2. Calibration Preparation
      • 3. Zoning Calibration
      • 4. T Calibration Progress Prompt
      • 5. Reference Video Calibration
    • Ⅵ. Views
      • 1. Device Properties
      • 2. Assets Properties
      • 3. Data Casting
    • Ⅶ. Software Settings
      • 1. Recording Settings
      • 2. View Settingss
      • 3. AI Settings
      • 4. Preferences
      • 5. Other Settings
    • Ⅷ. Calibration Categories
      • 1. Preparing for Calibration
      • 2. Basic Calibration
      • 3. Updating Calibration
      • 4. Origin Point Calibration
      • 5. Partial Calibration
      • 6.Ground Calibration
      • 7. Calibration-free (Anchor Calibration)
      • 8. side-mounted Camera / inverted Camera
    • Ⅸ. Markerset Creation
      • 1. Rigid
      • 2. Body
      • 3. Custom template
      • 4. Agent
      • 5. Asset Library
      • 6.Probe
      • 7.Scene library
    • Ⅹ. Data Collection and Fast Playback
      • 1. Data Collection
      • 2. Fast Playback
    • Ⅺ. Data Analysis
      • 1. Analyze Graphs
      • 2. Skeleton Graphs
      • 3. Analog Graphs
      • 4. Force Plate Data
      • 5. Health Graphs
      • 6. VMarker Graphs
    • Ⅻ. Data Processing
      • 1. Importing Data
      • 2. Create MarkerSet (Rigid)
      • 3. Use Existing MarkerSet
      • 4. Data Restoration
      • 5. Template Creation
      • 6. Template Identification and Tracking
      • 7. Data Rectification
      • 8. Use MarkerSet in Real-Time
      • 9. Marker Editing
      • 10.Marker switching
      • 11.Multi-frame recognition
    • XIII. Data Export
      • 1. Ly Files
      • 2. XRS Files
      • 3. TRC Files
      • 4. BVH Files
      • 5. HTR Files
      • 6. FBX Files
      • 7. Dynamics Files
      • 8. C3D Files
      • 9. ANC Files
      • 10. Exporting Forces Files
      • 11. Packing motion capture data
    • XIV. Human Body Template
      • 1. 53 Markers and Skeleton Definitions
      • 2. Helen Hayes Model
      • 3. Gloved Setup for 53-Marker Template
      • 4.CGM2 Body Model
      • 5.Finger Marker Point Instructions
      • 6. Explanation of 59-Point Finger Attachment
      • 7. Explanation of 63-Point Finger Attachment
      • 8.PlugIn Gait Marker Placement Instructions
    • XV. Data Retargeting
      • 1. Importing Model Assets
    • XVI. Third-Party Integrations
      • Force Plates
        • Bertec
        • KUNWEI
        • AMTI
        • Kistler
        • Aili Intelligent
        • General configuration
          • Import/Export Force Plate Config Files
          • Force and Torque
          • Other Configurations
      • EMG
        • ZHIYUNWEI
        • Distributed Wireless Electromyography
        • Delsys
        • Cometa
        • Noraxon
      • High-Speed Industrial Cameras
        • Standard industrial camera
        • Alkeria
        • HUIDIAN
        • DAHENG
        • DITECT
        • Network camera
        • FLIR Industrial Camera
      • Inertial Gloves
        • Glove management
        • Manus
        • VRTRIX
        • Diver-X
          • Installation and Calibration Configuration
          • Creating a Human Body Model with Gloves
    • XVII. Plugins & SDKs
      • 1. Unreal Engine (UE) Plugin
      • 2. Guide to Connecting Devices and Integrating VRPN Data with UE
      • 3. Use VRPN Data to Drive Rigid Body in UE
      • 4. MotionBuilder Plugin
      • 5. Maya Plugin
      • 6. Unity Plugin
      • 7. IClone Plugin
      • 8. Application of TimeCode in UE
      • 9.C4D Plugin
      • 10.Blender plugin
      • 11.Open VR Plugin
      • 12. Communication between Ros2 and Nokov
    • XVIII. UDP Capture Broadcast/Triggering
      • 1. Remote Control
      • 2. Remote Trigger
    • XVIIII.Log
      • 1.DisplayLog
Powered by GitBook
On this page
  1. XINGYING4.0
  2. Ⅸ. Markerset Creation

6.Probe

Previous5. Asset LibraryNext7.Scene library

Built-in probe model

The system has built-in NOKOV Probe Template (9.6.1),Model: LY-0020;

  1. Take the NOKOV probe-LY-0020 in the middle of the field, click Freeze, select the probe Markers, right-click the mouse and select "Create Probe", select "Built-in", select "LY-0020" as the template, and click 'Create' (9.6.2) ;

  1. After successfully creating the probe, the asset Interface will display the information of the created probe, and the 3D view will show the rigid body of the created probe;

Note: Other probes cannot be successfully created using the built-in probe template;

Custom probe model

  1. Stand the custom probe upright in the middle of the field, click Freeze, select the probe points by dragging a box around them, right-click the mouse and choose "Create Probe," then select the 'Custom' from the displayed window;

  2. Enter the probe name and calibration frames, then click Create. (In custom mode, clicking Create will automatically unfreeze the state);

  3. At this point, rotate the probe around a fixed point to form a cone shape and capture the specified number of frames. After collecting the required frames, the 3D view will display the created probe rigid body;

Note: While rotating the probe, ensure that the tip of the probe remains fixed at a point and does not move.

Note: Clicking Cancel during the collection process will stop data collection and calibration.

Probe Properties

  1. After selecting the probe asset, click on the probe properties icon (9.6.3) to display the properties window (9.6.4) ;

  1. On this page, clicking on "Calibrate" allows for recalibration of the selected and created probe. In real-time probe measurements, the real-time probe tip data is displayed;

  2. After clicking on "Calibrate," the interface will show the probe data collection status. At this point, rotate the probe around a fixed point to form a cone shape and start collecting data for calibration. Clicking Cancel will stop the calibration process. Upon completing the calibration, the updated rigid body will be displayed in the view;

6.1
9.6.2
9.6.3
9.6.4