3. Zoning Calibration
- The device list now includes a "Area Setting" menu, allowing users to divide the connected cameras into different areas.(5.3.1);
.png)
.png)
- Based on the actual layout of the site, add cameras to different areas (5.3.2).
- Perform L+T calibration by area. When calibrating Area 1, enable only the cameras for Area 1 and disable the cameras for other areas. After completing the calibration, save the calibration file as setup-area1.cal.
- Repeat the above steps to calibrate all zones in sequence, saving the calibration files for each zone to be used in the next step when merging calibrations.
- Once all areas have been calibrated, open the Calibration-Settings-Area Merge page (5.3.3). Select the calibration files for Area 1 and Area 2, set the parameters for XYZ offset, and click Merge.
.png)
- Update the calibration for the merged site. Once the updated calibration is complete, capturing can proceed normally.
- If there are three or more areas, first complete the merging of Area 1 and Area 2. Then, treat the merged area as Area 1 and merge it with Area 3. Proceed in this manner until all areas have been merged.
tip
Method for Measuring XYZ Offset:
- Designate Area 1 as the main site and Area 2 as the site to be merged.
- Measure the coordinate offset:
- Use the L-shaped rod of Area 1 as the origin of the coordinate axis and measure the distance between the L-shaped rod of Area 2 and the L-shaped rod of Area 1.